'Information never will sleep!'

Our IT solution division is ready for the all of cases to solve your problems. Do you haven’t got any problems in your company IT? It’s a good news for you, but as like as the information never will sleep like a devil. 

Server solutions

18 years professional experience

professional datacenter locations across Europe

7/24 technical support

our high availability is 99,9%

fault tolerant systems

You can rent from us a dedicate server or you can find a good locations for your server in our datacenter locations. Professional environment on a budget friendly cost. 

Surface area: 21.000 m2

Power supply: 32 MW of electrical power are provided to the servers. The system is entirely redundant and equipped with double conversion UPS systems.

Location: Slough, Berkshire, United Kingdom

Redundant power generators:

The data center is equipped with autonomous power generators with underground fuel tanks able to provide energy to the entire data center even at full capacity. These generators start providing energy after the batteries from the UPS system.

Redundancy of air conditioning systems:

The air conditioning systems in server and power rooms are made of multiple redundant appliances with a cooling capacity of 1.5 kW/m².

Bandwidth of 20 Gb/s:

Our installation benefits from a bandwidth of 20 Gb/s, provided through fiber-optic connections to the most important national and international service providers and to the main network access points (NAP).

Physical security:

The data center has automatic fire detection and suppression systems, harmless for the people and the electronic appliances. A system dedicated to the detection of leaks and flood is also present. The building is also equipped with armored doors and windows, an intrusion alarm system and a biometric access control.
Finally, a close circuit television system (CCTV) enables the monitoring of the entire building.

Monitoring 24×7:

The data center is controlled by a monitoring team 24/7 and 365 days a year and is moreover monitored by our technical team.

Certifications ISO 9001 e ISO 27001:

The data center is certified ISO 9001:2015 and ISO 27001:2013 for its quality.

Surface area: 6.000 m2

Power supply: 10 MW of electrical power are provided to the servers. The system is entirely redundant and equipped with double conversion UPS systems.

Location: Paris Saint-Denis, France

Redundant power generators:

The data center is equipped with autonomous power generators with underground fuel tanks able to provide energy to the entire data center even at full capacity. These generators start providing energy after the batteries from the UPS system.

Redundancy of air conditioning systems:

The air conditioning systems in server and power rooms are made of multiple redundant appliances.

Bandwidth of 20 Gb/s:

Our installation benefits from a bandwidth of 20 Gb/s, provided through fiber-optic connections to the most important national and international service providers and to the main network access points (NAP).

Physical security:

The data center has automatic fire detection and suppression systems, harmless for the people and the electronic appliances. A system dedicated to the detection of leaks and flood is also present. The building is also equipped with armored doors and windows, an intrusion alarm system and a biometric access control.
Finally, a close circuit television system (CCTV) enables the monitoring of the entire building.

Monitoring 24×7:

The data center is controlled by a monitoring team 24/7 and 365 days a year and is moreover monitored by our technical team.

Certifications ISO 9001:

The data center is certified ISO 9001:2015 for its quality.

Surface area: 5.000 m2

Capacity: More than 40.000 physical servers

Location: Arezzo, Italy

Tier 4*/Rating 4:

The data center has been designed according to Tier 4*/Rating 4 redundancy criteria, the highest rating for data centers.

Uptime:

The data center has an uptime of 100% since its launch in July 2011.

Power supply:

4.5 Mega Watt of electrical power are provided to the servers, with a complete redundancy thanks to two separated Power Centers. Each Power Center has the capacity to power the data center on its own, even at full capacity, and is equipped with double conversion UPS systems with high energetic efficiency (2N type redundancy).

Redundancy of Power Centers even for units with single power supply:

For its own services, IPG exclusively uses servers and appliances with double power supplies. Each Power Center is however backed-up by STS appliances (static Transfer Switch) able to ensure power continuity even to the appliances using single power units.

Separated buildings for general power supply and UPS battery systems:

In order to ensure a maximum security level for server rooms, power supply systems and UPS batteries are placed in 2 dedicated buildings, physically separated from the data center.

Fire resistant power cables:

We exclusively use power cables that are equipped with MGT (Mica Glass Tape), a fire barrier coating able to ensure power continuity even in cases of localized fires.

Redundant power generators with 48 hours of autonomy at full capacity:

The data center is equipped with autonomous power generators with underground fuel tanks able to provide energy for 48 hours at full capacity without refueling.

Green data center:

We have put a lot of attention in the optimization of the data center in terms of energy consumption. The entire cooling system of the server rooms has been equipped with highly effective direct expansion appliances, linked together in a network and optimized by a system able to adjust the level of cooling provided.

The building is also equipped with a free-cooling system. Through the use of colder outside air, meticulously filtered and corrected at humidity and temperature level, we are able to reduce the use of heat pumps and thus reduce the energy consumption and the impact on the environment. Finally, the server racks are equipped with an innovating system of cold air management, concentrating colder air on the front of the servers and enabling better energy efficiency.

Redundancy of air conditioning systems under UPS protection:

The air conditioning systems in server and power rooms are made of multiple redundant appliances able to guarantee a perfect functioning of the cooling even in case of simultaneous unit failures. The entire installation is protected by a UPS system with batteries and power generators to avoid any interruption.

Bandwidth of 82 Gb/s:

The data centers IT1 and IT2 are inter-connected through a dedicated and redundant fiber-optic network. They total a bandwidth of 82Gb/s of Internet connectivity, provided through fiber-optic connections to the most important national and international service providers and to the main network access points (NAP).

Advanced Networking:

Each server rack is fitted with multiple redundant connections, made-up of fiber-optic cables and able to route up to 100Gb/s of traffic, as well as copper network cables (category 7A) able to route up to 10Gb/s of traffic. The central network is equipped with Cisco Nexus 7000 units, which are the most advanced on the market.

Physical security:

The data center has automatic fire detection and suppression systems, working with inert gas which is harmless for the staff and the electronic appliances. A system dedicated to the detection of leaks and flood is also present.

The building is also equipped with armored doors and windows, an anti-climbing wall and an intrusion alarm system installed in each alley and connected to the double identification access control system. Finally, a close circuit television system (CCTV) with more than a hundred cameras enables us to monitor the entire building.

Monitoring 24×7:

The data center is controlled by a monitoring team 24/7 and 365 days a year. In addition to this, the data center is equipped with a BMS (Building Management System) able to inform in real time a secondary technical team in case of issues while giving them the possibility to remotely manage the machines.

Certifications ISO 9001 and ISO 27001:

The data center is certified ISO 9001:2015 for its quality and ISO 27001:2013 for its security level.

* The term ‘Tier’ was used in the ANSI/TIA-942 Standard until the ANSI/TIA-942:March-2014 edition. In the March 2014 edition the term ‘Tier’ has been replaced by either ‘Rated’ or ‘Rating’.

Surface area: 2.000 m2

Capacity: More than 10.000 physical servers.

Location: Arezzo, Italy

Uptime:

The data center has an uptime of 99.97% since its launch in May 2003.

Power supply:

1.8 Mega Watt of electrical power is provided to the servers, with a complete redundancy thanks to two separated Power Centers. Each Power Center has the capacity to power the data center on its own, even at full capacity, and is equipped with double conversion UPS systems with high energetic efficiency (2N type redundancy).

Redundancy of Power Centers even for units with single power supply:

For its own services, IPG exclusively uses servers and appliances with double power supplies. Each Power Center is however backed-up by STS appliances (static Transfer Switch) able to ensure power continuity even to the appliances using single power units.

Separated buildings for general power supply and UPS battery systems:

In order to ensure a maximum security level for server rooms, power supply systems and UPS batteries are placed in 2 dedicated buildings, physically separated from the data center.

Redundant power generators:

The data center is equipped with autonomous power generators with underground fuel tanks able to provide energy to the entire datacenter even at full capacity. These generators start providing energy after the batteries from the UPS system.

Green data center:

We have put a lot of attention in the optimization of the data center in terms of energy consumption. The entire cooling system of the server rooms has been equipped with highly effective direct expansion appliances, linked together in a network and optimized by a system able to adjust the level of cooling provided.

The building is also equipped with a free-cooling system. Through the use of colder outside air, meticulously filtered and corrected at humidity and temperature level, we are able to reduce the use of heat pumps and thus reduce the energy consumption and the impact on the environment. Finally, the server racks are equipped with an innovating system of cold air management, concentrating colder air on the front of the servers and enabling better energy efficiency.

Redundancy of air conditioning systems under UPS protection:

The air conditioning systems in server and power rooms are made of multiple redundant appliances able to guarantee a perfect functioning of the cooling even in case of simultaneous unit failures.
The entire installation is protected by a UPS system with batteries and power generators to avoid any interruption.

Bandwidth of 82 Gb/s:

The data centers IT1 and IT2 are inter-connected through a dedicated and redundant fiber-optic network. They total a bandwidth of 82Gb/s of Internet connectivity, provided through fiber-optic connections to the most important national and international service providers and to the main network access points (NAP).

Advanced Networking:

Each server rack is fitted with multiple redundant connections.
The central network is equipped with Cisco Nexus 7000 units, which are the most advanced on the market.

Physical security:

The data center has automatic fire detection and suppression systems, working with inert gas which is harmless for the staff and the electronic appliances. A system dedicated to the detection of leaks and flood is also present.
The building is also equipped with an intrusion alarm system installed in each alley and connected to the double identification access control system. Finally, a close circuit television system (CCTV) with more than a forty cameras enables us to monitor the entire building.

Monitoring 24×7:

The data center is controlled by a monitoring team 24/7 and 365 days a year. In addition to this, the data center is equipped with a BMS (Building Management System) able to inform in real time a secondary technical team in case of issues while giving them the possibility to remotely manage the machines.

Certifications ISO 9001 and ISO 27001:

The data center is certified ISO 9001:2015 for its quality and ISO 27001:2013 for its security level.

Surface area: 19.000 m2

Power supply: 10 MW of electrical power are provided to the servers. The system is entirely redundant and equipped with double conversion UPS systems.

Location: Frankfurt, Germany

Redundant power generators:

The data center is equipped with autonomous power generators with underground fuel tanks able to provide energy to the entire data center even at full capacity. These generators start providing energy after the batteries from the UPS system.

Redundancy of air conditioning systems:

The air conditioning systems in server and power rooms are made of multiple redundant appliances with a cooling capacity of 1.5 kW/m².

Bandwidth of 20 Gb/s:

Our installation benefits from a bandwidth of 20 Gb/s, provided through fiber-optic connections to the most important national and international service providers and to the main network access points (NAP).

Physical security:

The data center has automatic fire detection and suppression systems, harmless for the people and the electronic appliances. A system dedicated to the detection of leaks and flood is also present. The building is also equipped with armored doors and windows, an intrusion alarm system and a biometric access control.
Finally, a close circuit television system (CCTV) enables the monitoring of the entire building.

Monitoring 24×7:

The data center is controlled by a monitoring team 24/7 and 365 days a year and is moreover monitored by our technical team.

Certifications ISO 9001 e ISO 27001:

The data center is certified ISO 9001:2015 and ISO 27001:2013 for its quality.

Surface area: 1.500 m2

Capacity: More than 5.000 physical servers

Location: Ktis, Czech Republic

Uptime:

The data center has an uptime of 100% since its launch in 2004.

Power supply:

1 Mega Watt of electrical power is provided to the servers, with a complete redundancy thanks to two separated Power Centers. Each Power Center has the capacity to power the data center on its own, even at full capacity, and is equipped with double conversion UPS systems with high energetic efficiency (2N type redundancy).

Separated buildings for general power supply and UPS battery systems:

In order to ensure a maximum security level for server rooms, power supply systems and UPS batteries are placed in 2 dedicated buildings, physically separated from the data center.

Redundant power generators:

The data center is equipped with autonomous power generators with underground fuel tanks able to provide energy to the entire datacenter even at full capacity. These generators start providing energy after the batteries from the UPS system.

Green data center:

We have put a lot of attention in the optimization of the data center in terms of energy consumption. The entire cooling system of the server rooms has been equipped with highly effective direct expansion appliances, linked together in a network and optimized by a system able to adjust the level of cooling provided.

The building is also equipped with a free-cooling system. Through the use of colder outside air, meticulously filtered and corrected at humidity and temperature level, we are able to reduce the use of heat pumps and thus reduce the energy consumption and the impact on the environment.

Redundancy of air conditioning systems:

The air conditioning systems in server and power rooms are made of multiple redundant appliances able to guarantee a perfect functioning of the cooling even in case of simultaneous unit failures.

Bandwidth of 30 Gb/s:

The data center benefits from a bandwidth of 30 Gb/s, provided through fiber-optic connections to the most important national and international service providers and to the main network access points (NAP).

Physical security:

The data center has automatic fire detection and suppression systems, working with FM-200 gas, harmless for the staff and the electronic appliances.

The building is also equipped with an intrusion alarm system installed in each alley and connected to the double identification access control system. Finally, a close circuit television system (CCTV) enables us to monitor the entire building.

Monitoring 24×7:

The data center is controlled by a monitoring team 24/7 and 365 days a year.

Surface area: 900 m2

Location: BIX, Budapest, Hungary

Redundant power generators:

The data center has two independent power generators with enough fuel storage to supply the whole data center with energy power at full capacity for 48 hours. These generators guarantee the running of the data center beyond the duration of the UPS system batteries.

Redundant air-conditioning system:

The air-conditioning system for the data rooms and technological systems is made up of multiple redundant modules.

100 Gb/s bandwidth:

The bandwidth at our facility is 100 Gb/s, with fiber optic connection to the major national and international providers and the main network access points (NAP).

Physical security:

The data center is equipped with a flood detection, automatic fire detection and fire extinguishing system, which is harmless to humans and IT systems. The site is also installed with a security perimeter system with CCTV video surveillance, 24/7 active security and access control using security passes.

Monitoring 24/7:

The data center is monitored by a technical team 24 hours a day, 365 days a year, and through remote management by our staff.

Surface area: 3.700 m2

Power supply: 16 MW of electricity available to the servers. Totally redundant infrastructure equipped with static UPS systems.

Location: Warsaw, Poland

Redundant power generators:

The data center has two independent power generators with enough fuel storage to supply the whole data center with energy power at full capacity for 48 hours. These generators guarantee the running of the data center beyond the duration of the UPS system batteries.

Redundant air-conditioning system:

The air-conditioning system for the data rooms and technological systems is made up of multiple redundant modules.

30 Gb/s bandwidth:

The bandwidth at our facility is 30 Gb/s, with fiber optic connection to the major national and international providers and the main network access points (NAP).

Physical security:

The data center is equipped with a flood detection, automatic fire detection and fire extinguishing system, which is harmless to humans and IT systems. The site is also installed with a security perimeter system with CCTV video surveillance, 24/7 active security and access control using security passes.
There is also a CCTV system monitoring the whole facility.

Monitoring 24/7:

The data center is monitored by a technical team 24 hours a day, 365 days a year, and through remote management by our staff.

ISO 9001 and ISO 27001 certified:

The data center has been awarded ISO 9001:2008 and ISO 27001:2013 certifications